Changing the pickup branch can affect product availability.
Uploaded logo will be displayed on header
Uploaded logo will be displayed on header
Drag & drop or Browse
Upload photoAre you sure you want to delete the photo?
Loading promotions. Please wait
Loading promotions. Please wait
Loading promotions. Please wait
Changing division would affect availability and pricing of products in your cart.
This website uses cookies to improve your online experience. By accepting you agree to allow us store cookies on your computer. Learn More
This website uses cookies to improve your online experience. By accepting you agree to allow us store cookies on your computer. Learn More
Changing your ship-to location may impact your product pricing and availability.
Do you want to proceed with this change?
You have a quote in your cart, so if you add this to your cart it will remove all products from your cart.
Please order your quote and then add this to the cart later or confirm to replace the cart with this product now.
Contact your local branch to check product availability.
to view your price and product availability
Contact your sales representative to confirm availability.
Min: 1 EA , Multiple 1 EA
MCCB (Moulded Case Circuit Breakers) Up To 600A | |
Mfrcode | SQD |
---|---|
Number Of Poles | 2 |
Application | POWER DISTRIBUTION |
Pkg Type | PK |
Pkg Qty | 1 |
Mfr Fullname | SQUARE D/TELEMECANIQUE |
Pkg UOM | EA |
Current Rating | 30 AMPERE |
Pkg Weight UOM | LB |
Interrupting Rating | 25 KILOAMPERE AT 240 VAC, 18 KILOAMPERE AT 480 VAC STAR/277 VAC OR 480 VAC, 14 KILOAMPERE AT 600 VAC STAR/347 VAC OR 600 VAC (UL/CSA/NOM) 25 KILOAMPERE AT 240 VAC, 18 KILOAMPERE AT 415 VAC (IEC) |
Catalog Number | HDA260304 |
Trip Setting | 350 TO 750 AMPERE |
Mfr UNSPSC | 39121601 |
Pkg Weight | 3 |
Product Name | PowerPact H |
Approval | UL, CSA |
Voltage Rating | 240/480/600 VAC AT 50/60 HZ, 480 VAC STAR/277 VAC AT 50/60 HZ, 600 VAC STAR/347 VAC AT 50/60 HZ (UL/CSA/NOM) 240/415 VAC AT 50/60 HZ (IEC) |
Used On | CLASS 612 I-LINE[R] PANELBOARD/SWITCHBOARD |
Electrical Connection | I-Line connection, line, lugs, load |
Awg Gauge | AWG 14...AWG 3/0 aluminum/copper terminal |
Packaging Made With Recycled Cardboard | Yes |
Device Application | distribution |
Circuit Breaker Application | HACR rated |
Magnetic Tripping Current | 750-750 A |
Mounting Height | 3 in |
Range | PowerPact |
Ambient Air Temperature For Operation | -25-70 °C |
Protected Poles Description | 2t |
Standards | UL, CSA, NEMA, NOM-003-SCFI-2000, IEC 60947-2 |
Length | 16 mm |
Mounting Mode | I-Line bracket) |
Removable Battery | No |
Eu Rohs Directive | Compliant with Exemptions |
Poles Description | 2P |
China Rohs Regulation | Product out of China RoHS scope. Substance declaration for your information |
Net Weight | 2.2 kg |
Weight | 2.2 kg |
Utilisation Category | category A |
Mercury Free | Yes |
---|---|
Pvc Free | Yes |
[Ics] Rated Service Breaking Capacity | 25 kA 220/240 V AC 50/60 Hz IEC 60947-2, 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2, 14 kA 500/525 V AC 50/60 Hz IEC 60947-2, 20 kA 250 V DC IEC 60947-2, 20 kA 500 V DC IEC 60947-2 |
Suitability For Isolation | yes IEC 60947-2 |
Terminal Identifier | AL150HD |
Communication Interface | Modbus, Ethernet |
Ip Degree Of Protection | front cover IP40 IEC 60529 |
Ambient Air Temperature For Storage | -50-85 °C |
Height | 3 in |
Depth | 86 mm |
Breaking Capacity | 25 kA 240 V AC 50/60 Hz UL 489, 18 kA 480 V AC 50/60 Hz, 14 kA 600 V AC 50/60 Hz, 20 kA 250 V DC |
Product Certifications | UL, CSA, NOM |
Local Signalling | switched off (OFF) 1 trip indicator green) |
Network Frequency | 50/60 Hz |
[Uimp] Rated Impulse Withstand Voltage | 8 kV IEC 60947-2 |
[Ue] Rated Operational Voltage | 690 V AC 50/60 Hz IEC 60947-3 |
Quality Labels | CE |
Breaking Capacity Code | D |
[In] Rated Current | 30-30 A |
Pollution Degree | 3 IEC 60947-1 |
Number Of Slots | 2 auxiliary switch OF plug-in), 1 alarm switch SD plug-in), 1 overcurrent trip switch SDE plug-in), 1 voltage release MN or MX plug-in) |
Tightening Torque | 5-5 N.m 2.5-6 mm² AWG 14...AWG 10), 14-14 N.m 10-95 mm² AWG 8...AWG 3/0) |
Width | 104 mm |
[Ui] Rated Insulation Voltage | 750 V IEC 60947-2 |
Wire Stripping Length | 16 mm |
Mounting Support | bracket |
Product Or Component Type | circuit breaker |
Quantity Per Set | 1 |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
Trip Unit Technology | thermal-magnetic |
Carbon Footprint (Kg Co2 Eq, Total Life Cycle) | 262.5485908 |
Country of Origin | United States |
Environmental Disclosure | ENVPEP2206027EN |
Circularity Profile | ENVEOLI2206027EN |
Operating Altitude | < 2000 m without derating, 5000 m with derating |
Continuous Current Rating | 0.8 |
Control Type | toggle |
Colour | black |
F-Gas (Fluorinated gases) government regulations specify that a limited number of products can be sold in the European Union that contain F-gases which have been linked to climate change.