Changing the pickup branch can affect product availability.
Uploaded logo will be displayed on header
Uploaded logo will be displayed on header
Drag & drop or Browse
Upload photoAre you sure you want to delete the photo?
Loading promotions. Please wait
Loading promotions. Please wait
Loading promotions. Please wait
Changing division would affect availability and pricing of products in your cart.
This website uses cookies to improve your online experience. By accepting you agree to allow us store cookies on your computer. Learn More
This website uses cookies to improve your online experience. By accepting you agree to allow us store cookies on your computer. Learn More
Changing your ship-to location may impact your product pricing and availability.
Do you want to proceed with this change?
You have a quote in your cart, so if you add this to your cart it will remove all products from your cart.
Please order your quote and then add this to the cart later or confirm to replace the cart with this product now.
Contact your local branch to check product availability.
to view your price and product availability
Contact your sales representative to confirm availability.
Min: 1 EA , Multiple 1 EA
MCCB (Moulded Case Circuit Breakers) Up To 600A | |
Pkg Weight | 5.57 |
---|---|
Trip Setting | 800 TO 1450 AMPERE |
Pkg UOM | EA |
Number Of Poles | 3 |
Interrupting Rating | 25 KILOAMPERE AT 240 VAC, 18 KILOAMPERE AT 480 VAC STAR/277 VAC OR 480 VAC, 14 KILOAMPERE AT 600 VAC STAR/347 VAC OR 600 VAC (UL/CSA/NOM) 25 KILOAMPERE AT 240 VAC, 18 KILOAMPERE AT 415 VAC (IEC) |
Approval | UL, CSA |
Pkg Height | 6.5 |
Mfr Fullname | SQUARE D/TELEMECANIQUE |
Mfrcode | SQD |
Pkg Width | 8.5 |
Used On | CLASS 612 I-LINE[R] PANELBOARD/SWITCHBOARD |
Current Rating | 80 AMPERE |
Product Name | MOLDED CASE CIRCUIT BREAKER |
Pkg Weight UOM | LB |
Mfr UNSPSC | 39121601 |
Voltage Rating | 240/480/600 VAC AT 50/60 HZ, 480 VAC STAR/277 VAC AT 50/60 HZ, 600 VAC STAR/347 VAC AT 50/60 HZ (UL/CSA/NOM) 240/415 VAC AT 50/60 HZ (IEC) |
Pkg Qty | 1 |
Pkg Type | PK |
Application | POWER DISTRIBUTION |
Pkg Length | 15 |
Catalog Number | HDA36080 |
Number Of Slots | 2 auxiliary switch OF plug-in), 1 alarm switch SD plug-in), 1 overcurrent trip switch SDE plug-in), 1 voltage release MN or MX plug-in) |
Breaking Capacity | 25 kA 240 V AC 50/60 Hz UL 489, 18 kA 480 V AC 50/60 Hz, 14 kA 600 V AC 50/60 Hz, 20 kA 250 V DC |
Rohs Exemption Information | Yes |
Weight | 2.2 kg |
Device Application | distribution |
Ambient Air Temperature For Operation | -25-70 °C |
Height | 163 mm |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
Mounting Height | 4.5 in |
Poles Description | 3P |
[Uimp] Rated Impulse Withstand Voltage | 8 kV IEC 60947-2 |
Network Frequency | 50/60 Hz |
Ambient Air Temperature For Storage | -50-85 °C |
Quantity Per Set | 1 |
Pollution Degree | 3 IEC 60947-1 |
Protected Poles Description | 3t |
[Ics] Rated Service Breaking Capacity | 25 kA 220/240 V AC 50/60 Hz IEC 60947-2, 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2, 14 kA 500/525 V AC 50/60 Hz IEC 60947-2, 20 kA 250 V DC IEC 60947-2, 20 kA 500 V DC IEC 60947-2 |
Depth | 86 mm |
Mounting Mode | I-Line bracket) |
Circularity Profile | ENVEOLI2206027EN |
---|---|
Country of Origin | Mexico |
Awg Gauge | AWG 14...AWG 3/0 aluminum/copper terminal |
Magnetic Tripping Current | 1450-1450 A |
Magnetic Hold Current | 800 A |
Electrical Connection | I-Line connection, line, lugs, load |
Take-Back | No |
Carbon Footprint (Kg Co2 Eq, Total Life Cycle) | 481.9677598 |
Operating Altitude | < 2000 m without derating, 5000 m with derating |
Tightening Torque | 5-5 N.m 2.5-6 mm² AWG 14...AWG 10), 14-14 N.m 10-95 mm² AWG 8...AWG 3/0) |
Ip Degree Of Protection | front cover IP40 IEC 60529 |
Quality Labels | CE |
Mounting Support | bracket |
Length | 16 mm |
Width | 104 mm |
Pvc Free | Yes |
Control Type | toggle |
Eu Rohs Directive | Compliant with Exemptions |
Product Or Component Type | circuit breaker |
Circuit Breaker Application | HACR rated |
Trip Unit Technology | thermal-magnetic |
Breaking Capacity Code | D |
Packaging Without Single Use Plastic | No |
Mercury Free | Yes |
Net Weight | 2.2 kg |
Local Signalling | switched off (OFF) 1 trip indicator green) |
Communication Interface | Modbus, Ethernet |
Product Certifications | UL, CSA, NOM |
[In] Rated Current | 80-80 A |
Utilisation Category | category A |
[Ue] Rated Operational Voltage | 690 V AC 50/60 Hz IEC 60947-3 |
Suitability For Isolation | yes IEC 60947-2 |
Phase Connection | ABC |
Standards | UL, CSA, NEMA, NOM-003-SCFI-2000, IEC 60947-2 |
Environmental Disclosure | ENVPEP2206027EN |
Terminal Identifier | AL150HD |
Packaging Made With Recycled Cardboard | Yes |
Continuous Current Rating | 0.8 |
Removable Battery | No |