Changing the pickup branch can affect product availability.
Uploaded logo will be displayed on header
Uploaded logo will be displayed on header
Drag & drop or Browse
Upload photoAre you sure you want to delete the photo?
Loading promotions. Please wait
Loading promotions. Please wait
Loading promotions. Please wait
Changing division would affect availability and pricing of products in your cart.
This website uses cookies to improve your online experience. By accepting you agree to allow us store cookies on your computer. Learn More
This website uses cookies to improve your online experience. By accepting you agree to allow us store cookies on your computer. Learn More
Changing your ship-to location may impact your product pricing and availability.
Do you want to proceed with this change?
You have a quote in your cart, so if you add this to your cart it will remove all products from your cart.
Please order your quote and then add this to the cart later or confirm to replace the cart with this product now.
Contact your local branch to check product availability.
to view your price and product availability
Contact your sales representative to confirm availability.
Min: 1 EA , Multiple 1 EA
MCCB (Moulded Case Circuit Breakers) Up To 600A | |
Approval | UL, CSA, CE |
---|---|
Pkg Length | 7.8 |
Mfr Fullname | SQUARE D/TELEMECANIQUE |
Pkg UOM | EA |
Pkg Weight UOM | LB |
Mfrcode | SQD |
Pkg Height | 7.2 |
Pkg Weight | 3.07 |
Frame Type | H |
Pkg Type | PK |
Size | 2.74 INCH W X 4.36 INCH D X 6.4 INCH H |
Number Of Poles | 2 |
Catalog Number | HDL26060 |
Additional Information | APPLICABLE STANDARD W-C-375B/GEN |
Voltage Rating | 240 VAC AT 50/60 HZ, 480 VAC STAR/277 VAC AT 50/60 HZ, 480 VAC AT 50/60 HZ, 600 VAC STAR/347 VAC AT 50/60 HZ, 600 VAC AT 50/60 HZ (UL/CSA/NOM) 240/415 VAC AT 50/60 HZ (IEC) 250 VDC |
Pkg Qty | 1 |
Type | MOLDED CASE, THERMAL MAGNETIC |
Interrupting Rating | 25 KILOAMPERE AT 240 VAC, 18 KILOAMPERE AT 480 VAC STAR/277 VAC OR 480 VAC, 14 KILOAMPERE AT 600 VAC STAR/347 VAC OR 600 VAC (UL/CSA/NOM) 25 KILOAMPERE AT 240 VAC, 18 KILOAMPERE AT 415 VAC (IEC) 250 VDC |
Product Name | PowerPact H |
Pkg Width | 6.3 |
Current Rating | 60 AMPERE |
Mfr UNSPSC | 39121601 |
Maximum DC Voltage Rating | 250 V |
Maximum AC Voltage Rating | 600 V |
Terminal Type | LINE LUG, LOAD LUG |
Ambient Air Temperature For Operation | -25-70 °C |
Trip Unit Technology | thermal-magnetic |
Quantity Per Set | 1 |
Magnetic Tripping Current | 1450-1450 A |
Network Frequency | 50/60 Hz |
Product Certifications | UL, CSA, NOM |
Packaging Made With Recycled Cardboard | Yes |
Take-Back | No |
Colour | black |
Poles Description | 2P |
Breaking Capacity | 25 kA 240 V AC 50/60 Hz UL 489, 18 kA 480 V AC 50/60 Hz, 14 kA 600 V AC 50/60 Hz, 20 kA 250 V DC |
Pvc Free | Yes |
Net Weight | 2.2 kg |
Circuit Breaker Application | HACR rated |
[Uimp] Rated Impulse Withstand Voltage | 8 kV IEC 60947-2 |
Suitability For Isolation | yes IEC 60947-2 |
Circularity Profile | ENVEOLI2206027EN |
---|---|
Awg Gauge | AWG 14...AWG 3/0 aluminum/copper terminal |
Product Or Component Type | circuit breaker |
[In] Rated Current | 60-60 A |
Local Signalling | switched off (OFF) 1 trip indicator green) |
Eu Rohs Directive | Compliant with Exemptions |
Operating Altitude | < 2000 m without derating, 5000 m with derating |
Ip Degree Of Protection | front cover IP40 IEC 60529 |
Utilisation Category | category A |
Standards | UL, CSA, NEMA, NOM-003-SCFI-2000, IEC 60947-2 |
Mounting Support | lug |
Weight | 2.2 kg |
Packaging Without Single Use Plastic | No |
Mounting Mode | unit mount lug) |
Pollution Degree | 3 IEC 60947-1 |
Rohs Exemption Information | Yes |
Width | 104 mm |
Ambient Air Temperature For Storage | -50-85 °C |
Length | 16 mm |
Communication Interface | Modbus, Ethernet |
Depth | 86 mm |
Height | 163 mm |
Range | PowerPact |
Mercury Free | Yes |
[Ui] Rated Insulation Voltage | 750 V IEC 60947-2 |
Continuous Current Rating | 0.8 |
China Rohs Regulation | Product out of China RoHS scope. Substance declaration for your information |
Number Of Slots | 2 auxiliary switch OF plug-in), 1 alarm switch SD plug-in), 1 overcurrent trip switch SDE plug-in), 1 voltage release MN or MX plug-in) |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
Control Type | toggle |
Carbon Footprint (Kg Co2 Eq, Total Life Cycle) | 293.0126428 |
Tightening Torque | 5-5 N.m 2.5-6 mm² AWG 14...AWG 10), 14-14 N.m 10-95 mm² AWG 8...AWG 3/0) |
Wire Stripping Length | 16 mm |
Breaking Capacity Code | D |
Terminal Identifier | AL150HD |
Environmental Disclosure | ENVPEP2206027EN |
Country of Origin | United States |
[Ics] Rated Service Breaking Capacity | 25 kA 220/240 V AC 50/60 Hz IEC 60947-2, 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2, 14 kA 500/525 V AC 50/60 Hz IEC 60947-2, 20 kA 250 V DC IEC 60947-2, 20 kA 500 V DC IEC 60947-2 |
Protected Poles Description | 2t |
Quality Labels | CE |
Electrical Connection | lugs, line, lugs, load |
F-Gas (Fluorinated gases) government regulations specify that a limited number of products can be sold in the European Union that contain F-gases which have been linked to climate change.