Changing the pickup branch can affect product availability.
Uploaded logo will be displayed on header
Uploaded logo will be displayed on header
Drag & drop or Browse
Upload photoAre you sure you want to delete the photo?
Loading promotions. Please wait
Loading promotions. Please wait
Loading promotions. Please wait
Changing division would affect availability and pricing of products in your cart.
This website uses cookies to improve your online experience. By accepting you agree to allow us store cookies on your computer. Learn More
This website uses cookies to improve your online experience. By accepting you agree to allow us store cookies on your computer. Learn More
Changing your ship-to location may impact your product pricing and availability.
Do you want to proceed with this change?
You have a quote in your cart, so if you add this to your cart it will remove all products from your cart.
Please order your quote and then add this to the cart later or confirm to replace the cart with this product now.
Contact your local branch to check product availability.
to view your price and product availability
Contact your sales representative to confirm availability.
Min: 1 EA , Multiple 1 EA
MCCB (Moulded Case Circuit Breakers) Up To 600A | |
Pkg Type | PK |
---|---|
Approval | UL, CSA, CE |
Pkg Weight | 4.2 |
Maximum AC Voltage Rating | 600 V |
Pkg Width | 6.4 |
Product Name | PowerPact H |
Pkg Length | 8.8 |
Size | 4.12 INCH W X 4.36 INCH D X 6.4 INCH H |
Pkg UOM | EA |
Interrupting Rating | 25 KILOAMPERE AT 240 VAC, 18 KILOAMPERE AT 480 VAC STAR/277 VAC OR 480 VAC, 14 KILOAMPERE AT 600 VAC STAR/347 VAC OR 600 VAC (UL/CSA/NOM) 25 KILOAMPERE AT 240 VAC, 18 KILOAMPERE AT 415 VAC (IEC) 250 VDC |
Pkg Weight UOM | LB |
Current Rating | 80 AMPERE |
Type | MOLDED CASE, THERMAL MAGNETIC |
Mfr Fullname | SQUARE D/TELEMECANIQUE |
Maximum DC Voltage Rating | 250 V |
Frame Type | H |
Voltage Rating | 240 VAC AT 50/60 HZ, 480 VAC STAR/277 VAC AT 50/60 HZ, 480 VAC AT 50/60 HZ, 600 VAC STAR/347 VAC AT 50/60 HZ, 600 VAC AT 50/60 HZ (UL/CSA/NOM) 240/415 VAC AT 50/60 HZ (IEC) 250 VDC |
Pkg Height | 7.3 |
Terminal Type | LINE LUG, LOAD LUG |
Number Of Poles | 3 |
Additional Information | APPLICABLE STANDARD W-C-375B/GEN |
Catalog Number | HDL36080 |
Mfr UNSPSC | 39121601 |
Pkg Qty | 1 |
Mfrcode | SQD |
Control Type | toggle |
Quantity Per Set | 1 |
Number Of Slots | 2 auxiliary switch OF plug-in), 1 alarm switch SD plug-in), 1 overcurrent trip switch SDE plug-in), 1 voltage release MN or MX plug-in) |
Poles Description | 3P |
Circuit Breaker Application | HACR rated |
Device Application | distribution |
Circularity Profile | ENVEOLI2206027EN |
Pvc Free | Yes |
Eu Rohs Directive | Compliant with Exemptions |
Quality Labels | CE |
Take-Back | No |
Ambient Air Temperature For Operation | -25-70 °C |
Suitability For Isolation | yes IEC 60947-2 |
Ip Degree Of Protection | front cover IP40 IEC 60529 |
Terminal Identifier | AL150HD |
Environmental Disclosure | ENVPEP2206027EN |
Standards | UL, CSA, NEMA, NOM-003-SCFI-2000, IEC 60947-2 |
---|---|
Width | 104 mm |
Pollution Degree | 3 IEC 60947-1 |
[Ui] Rated Insulation Voltage | 750 V IEC 60947-2 |
Network Frequency | 50/60 Hz |
Awg Gauge | AWG 14...AWG 3/0 aluminum/copper terminal |
Continuous Current Rating | 0.8 |
Packaging Without Single Use Plastic | No |
Tightening Torque | 5-5 N.m 2.5-6 mm² AWG 14...AWG 10), 14-14 N.m 10-95 mm² AWG 8...AWG 3/0) |
Net Weight | 2.2 kg |
[In] Rated Current | 80-80 A |
Mounting Mode | unit mount lug) |
Protected Poles Description | 3t |
Trip Unit Technology | thermal-magnetic |
Colour | black |
Range | PowerPact |
Carbon Footprint (Kg Co2 Eq, Total Life Cycle) | 478.7273047 |
Rohs Exemption Information | Yes |
Magnetic Hold Current | 800 A |
Length | 16 mm |
Breaking Capacity Code | D |
Weight | 2.2 kg |
Wire Stripping Length | 16 mm |
Height | 163 mm |
Electrical Connection | lugs, line, lugs, load |
[Uimp] Rated Impulse Withstand Voltage | 8 kV IEC 60947-2 |
Country of Origin | United States |
Utilisation Category | category A |
Mercury Free | Yes |
[Ics] Rated Service Breaking Capacity | 25 kA 220/240 V AC 50/60 Hz IEC 60947-2, 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2, 14 kA 500/525 V AC 50/60 Hz IEC 60947-2, 20 kA 250 V DC IEC 60947-2, 20 kA 500 V DC IEC 60947-2 |
Local Signalling | switched off (OFF) 1 trip indicator green) |
Depth | 86 mm |
Operating Altitude | < 2000 m without derating, 5000 m with derating |
[Ue] Rated Operational Voltage | 690 V AC 50/60 Hz IEC 60947-3 |
Mounting Support | lug |
Communication Interface | Modbus, Ethernet |
Product Certifications | UL, CSA, NOM |
Breaking Capacity | 25 kA 240 V AC 50/60 Hz UL 489, 18 kA 480 V AC 50/60 Hz, 14 kA 600 V AC 50/60 Hz, 20 kA 250 V DC |
Packaging Made With Recycled Cardboard | Yes |
China Rohs Regulation | Product out of China RoHS scope. Substance declaration for your information |
Ambient Air Temperature For Storage | -50-85 °C |
F-Gas (Fluorinated gases) government regulations specify that a limited number of products can be sold in the European Union that contain F-gases which have been linked to climate change.
We encourage you to find products that meet your needs and do not contain these gases.